产品规格
BX53M Specifications (for Reflected and Reflected/Transmitted Light Combination)
BX53MTRF-S | BX53MRF-S | BXFM | ||
---|---|---|---|---|
Optical system | UIS2 optical system (infinity-corrected) | |||
Microscope frame | Illumination | Reflected/transmitted | Reflected | |
Focus | Stroke: 25 mm Fine stroke per rotation: 100 μm Minimum graduation: 1 μm With upper limit stopper, torque adjustment for coarse handle |
Stroke: 30 mm Fine stroke per rotation: 200 μm Minimum graduation: 2 μm With torque adjustment for coarse handle | ||
Max. specimen height | 35 mm (w/o spacer) 75 mm (with BX3M-ARMAD) | 65 mm (w/o spacer) 105 mm (with BX3M-ARMAD) | Depends on the mounting configuration | |
Observation tube | Wide-field FN 22 | Inverted: binocular, trinocular, tilting binocular Erect: trinocular, tilting binocular |
||
Super-wide-field FN 26.5 | Inverted: trinocular Erect: trinocular, tilting trinocular |
|||
Reflected light illumination | Traditional observation technique | BX3M-RLAS-S Coded, white LED, BF/DF/DIC/POL/MIX FS, AS (with centering mechanism), BF/DF interlocking BX3M-KMA-S White LED, BF/DIC/POL/MIX FS, AS (with centering mechanism), BF/DF interlocking BX3M-RLA-S 100W/50W halogen lamp, white LED, BF/DF/DIC/POL/MIX/ FS, AS (with centering mechanism), BF/DF interlocking, ND filter |
||
U-KMAS White LED, 100W halogen Fiber illumination, BF/DIC/POL/MIX |
||||
Fluorescence | BX3M-URAS-S Coded, 100W mercury lamp, 4 position mirror unit turret, (standard: WB, WG, WU+BF etc) With FS, AS (with centering mechanism), with shutter mechanism |
|||
Transmitted light | White LED Abbe/long working distance condensers |
|||
Revolving nosepiece | For BF | Sextuple, centering sextuple, septuple, coded quintuple (optional motorized revolving nosepieces) | ||
For BF/DF | Sextuple, quintuple, centering quintuple, coded quintuple (optional motorized revolving nosepieces) | |||
Stage | Coaxial left (right) handle stage: 76 mm × 52 mm, with torque adjustment Large-size coaxial left (right) handle stage: 105 mm × 100 mm, with locking mechanism in Y-axis Large-size coaxial right handle stage: 50 mm × 100 mm, with torque adjustment and locking mechanism in Y-axis | |||
Weight | Approx. 18.3 kg (Microscope frame 7.6 kg) | Approx. 15.8 kg (Microscope frame 7.4 kg) | Approx. 11.1 kg (Microscope frame 1.9 kg) |
BX53M Specifications (for IR Observation)
BX53MRF-S | BXFM | ||
---|---|---|---|
IR Observation tube | Wide field FN 22 | Inverted: trinocular | |
Reflected light illumination | IR observation | BX3M-RLA-S 100W/50W halogen lamp for IR, BF/IR, AS (with centering mechanism), with band pass filter (1100 nm, 1200 nm) BX3M-URAS-S 100W/50W halogen lamp for IR, BF/IR, AS (with centering mechanism), with band pass filter (1100 nm, 1200 nm), with shutter mechanism | |
U-KMAS 100W/50W halogen for IR, BF/IR |
|||
Revolving nosepiece | For BF | Sextuple, centering sextuple, septuple, coded quintuple (optional motorized revolving nosepieces) | |
Stage (X × Y) | Coaxial left (right) handle stage: 76 mm × 52 mm, with torque adjustment Large-size coaxial left (right) handle stage: 105 mm × 100 mm, with locking mechanism in Y-axis Large-size coaxial right handle stage: 150 mm × 100 mm, with torque adjustment and locking mechanism in Y-axis | ||
Weight | Approx. 18.9 kg (Microscope frame 7.4 kg) | Approx. 11.6 kg (Microscope frame 1.9 kg) |
BX53M Specifications (for Polarized Observation)
BX53MTRF-S | ||
Polarized light intermediate attachment (U-CPA or U-OPA) | Wide field FN 22 | Inverted: binocular, trinocular, tilting binocular Erect: trinocular, tilting binocular |
Bertrand lens | Focusable (for U-CPA only) | |
Bertrand field stop | ø3.4 mm diameter (fixed) (for U-CPA only) | |
Engage or disengage Bertrand lens changeover between orthoscopic and conoscopic observation | Position of slider ● in Position of slider ○ out (for U-CPA only) | |
Analyzer Slot | Rotatable analyzer with slot (U-AN360P-2) | |
Analyzer (U-AN360P-2) | 360° dial-rotatable Rotatable minimum angle 0.1° | |
Revolving centerable nosepiece (U-P4RE) | Quadruple, centerable attachable components: 1/4 wavelength retardation plate (U-TAD), tint plate (U-TP530) and various compensators can be attached using plate adapter (U-TAD) | |
Stage (U-SRP) | Polarizing rotatable stage with 3-point centering function 360° rotatable, lockable in any position, 360° graduated in 1° increments (minimum retardation resolution 6', using vernier scale) 45° click stop function Mechanical stage (U-FMP) can be attached |
|
Condenser (U-POC-2) | Achromat strain-free condenser (U-POC-2), 360° rotatable polarizer with swing-out achromatic top-lens Click stop at position "0°" is adjustable NA 0.9 (top-lens in) NA 0.18 (top-lens out) Aperture iris diaphragm: adjustable from 2 mm to 21 mm diameters |
|
Weight | Approx. 16.2 kg (Microscope frame 7.6 kg) |
BX53M/BXFM ESD Units
Items | Microscope frame: BX53MRF-S, BX53MTRF-S Illuminator: BX3M-KMA-S, BX3M-RLA-S, BX3M-URAS-S, BX3M-RLAS-S Nosepiece: U-D6BDRES-S, U-D6RE-ESD, U-D5BDREMC-ESD, U-5RES-ESD Stage: U-SIC4R2, U-SIC4L2, U-MSSP4 |
---|
相关产品