Product Description
Electromagnetic film thickness meter LE-370 | Eddy current film thickness meter LH-370 | Dual function film thickness meter LZ-370 |
---|---|---|
![]() |
![]() |
![]() |
Dedicated printer VZ-320 | Measuring stand LW-990 | Data management software L.DL-02 | Data management software McWave series |
---|---|---|---|
![]() |
![]() |
![]() |
![]() |
Chinese interface (four language versions) | With continuous scanning measurement function |
---|---|
There are four operating versions in Chinese, Japanese, English, and Korean, and the operation is simple and clear. | The 370 series film thickness gauge is equipped with "single point measurement" and "continuous scanning measurement" functions, which are widely used in various surface conditions and eliminate measurement disputes. |
Memory capacity of 100 sets of calibration curves | With data transmission function |
The user can classify all the workpieces and create the calibration curves separately, which can be used immediately after turning on the machine, without re-calibration. | The measured value can be connected to a dedicated printer VZ-330 (optional) or connected to a computer, and it can be transmitted immediately during measurement or after measurement. |
Measured value with reference function | Meet the specification |
The measured value of the work site can be memorized at most 3000 ratios. The user can check each measurement value one by one under the function of "delete data". | :JIS K5600, JIS H8680, BS 5411, BS 3900, ISO 2808, ISO 2178, ISO 2360, SSPC-PA2, ASTM B499, ASTM B244, BS EN, ISO 1416, DIN 50984, DIN 50981, etc. |
With statistical average function | |
The statistical calculation range can be set by the user, and the maximum, minimum, average and standard deviation values can be calculated statistically. |
Product Feature
![]() |
Dual function film thickness meter |
---|---|
Both magnetic metal and non-magnetic metal substrates can be measured | |
Automatic material identification | |
Automatic material discrimination, automatic measurement mode switching | |
Calibration curve memory function | |
With 16 calibration curves to establish memory capacity | |
Statistical average function | |
Calculate the average, maximum, minimum, standard deviation, etc. | |
Data output | |
Measurement results can be transferred to a computer or printed | |
Chinese display model | |
Built-in display in Japanese, Japanese, Korean, English and other languages |
![]() |
Compliance with specifications: JIS K5600, JIS H8680, BS 5411, BS 3900, ISO 2808, ISO 2178, ISO 2360, SSPC-PA2, ASTM B499, ASTM B244, BS EN, ISO 1416, DIN 50984, DIN 50981, etc. |
Product Specification
Official style | LZ-990 |
---|---|
test methods | Electromagnetic and eddy current dual-purpose type (automatic discrimination function) |
Measurement object | Non-magnetic coating on magnetic metal Insulating film on non-magnetic metal |
Measuring range | 0~200um or 0~80.omils |
Measurement accuracy | Within 50um±1um, above 50um to 1000um±2%, above 1000um to 2000um±3% |
Minimal analysis | 0.1um within 100um, 1um above 100um |
Display method | 128x64 dot backlit LCD numerical display |
Backlight setting | The backlight intensity has no backlight, dark, normal, bright, etc. for selection. The backlight time is 5 seconds, 10 seconds and 20 seconds for choice |
Data memory | About 1000 points, with search function |
total caculation | Calculate the average, maximum, minimum, standard deviation, etc. |
Calibration curve | There are 8 groups each for electromagnetic type and eddy current type, totaling 16 groups. Calibration curve, memory capacity, direct use at any time |
Curve creation | Simple calibration: two-point calibration method (small range) Multi-point calibration: five-point calibration method (full range) |
power supply | Battery 1.5V (single AAA alkaline battery) X2 |
Power consumption | 40mW (when the backlight is not turned on) |
Battery Life | 60 hours (continuous use when the backlight is not turned on) |
Power saving function | When the instrument is not in use, it has an automatic shutdown and power saving function. With 5 points, 10 points, 20 points without automatic shutdown for selection |
Operating environment | 0~40℃ |
Limit setting | With upper and lower limit judgment function, with arrows and sound warning |
Function application | Calibration line memory, measurement data memory, data deletion, data output, lot number distinction, automatic power on/off function, built-in clock function, upper and lower limit setting, statistical calculation, backlight display function, unit setting, etc. |
Data output | Can be connected to a computer (USB) or printer (RS-232C) |
size and weight | 82(W) x 99.5 (D) x 32 (H)mm, about 160g |
Standard accessories | Iron material, aluminum material, 3 standard films (about 50. 100. 1000um, depending on the production size). Carrying package battery 1.5V (single AAA alkaline battery) X2, operating instructions. |
Optional accessories | Standard film (thickness other than accessories), measuring stand LW-990 dedicated printer VZ-330, printer dedicated transmission line, USB computer transmission line, transparent protective film |
model | LE-370 | LH-370 | LZ-370 |
---|---|---|---|
measurement method | Electromagnetic induction | Eddy current | Electromagnetic/eddy current dual purpose |
Measurement object | Non-magnetic coating on magnetic metal | Insulating film on non-magnetic metal | Two items on the left |
Measuring range | 0~2500um or 0~99.omils | 0~1200um or 0~47.omils | Two items on the left |
Determination type | Single point contact constant pressure (LEP-J) | Single-point contact constant pressure type (LHP-J) | Two items on the left |
Measurement accuracy | Within 50um: ±1um; above 50um to within 1000u: ±2%; above 1000um: ±3% | ||
Resolution | Below 100um: 0.1; Above 100um: 1um | ||
Calibration curve | 100 sets of calibration curve memory | 100 sets of calibration curve memory | Electromagnetic type 50 groups, eddy current type 5 groups |
Data memory | Approximately 3000 points of data, with data access function | ||
Measurement method | With single point measurement and continuous scanning measurement function | ||
Display method | Backlit LCD 128 X 64 dots numerical display, minimum resolution 0.1um | ||
External output | Data can be output to a personal computer or dedicated printer (RS-232C) | ||
power supply | Single AA alkaline battery 1.5V X4 | ||
power consumption | 80mW (when the backlight is off) | ||
Battery Life | About 100 hours (continuous use, when the backlight is off) | ||
Operating environment | 0~40℃ | ||
Application function | Calibration curve selection, material correction, data deletion, data memory, upper and lower limit setting, statistical calculation, display selection, date and time, automatic shutdown time, backlight brightness, backlight time, unit switching, data output, automatic batch number distinction, measurement method, Maintenance mode | ||
size and weight | 75(W) x 145(D) x 31(H)mm, 340g | ||
Standard accessories | Standard film box, single AA alkaline battery 1.5V x 4, curved holder, carrying leather case | ||
Exclusive accessories | Iron material, 6 standard films | Aluminum material, 5 standard films | Iron and aluminum materials, 6 standard sheets |
Optional equipment | Data management software L.DL-02, data management software McWave series, standard film, measuring station LW-990, dedicated printer VZ-330, printer transmission line, computer transmission line, RS232C & USB conversion line |