How to maintain the molds of a metallographic hot mounting machine?
The maintenance of the metallographic hot mounting machine mold is very important. After use, residual mounting material inside the mold must be cleaned in a timely manner; tools can be used to carefully remove them to prevent residues from affecting the next use and mold precision.
For some stubborn residues, appropriate solvents can be used for cleaning after soaking, but care must be taken that the solvent does not cause corrosion to the mold material.
Regularly check the dimensional accuracy and surface finish of the mold; if mold wear or deformation is found, it should be repaired or replaced in a timely manner to ensure that the dimensions of the mounted samples are accurate, forming regular mounting blocks with a height of about 20mm and a diameter of about 30mm.
When storing the mold, place it in a dry and clean environment to avoid moisture and rust. A layer of anti-rust oil can be applied to the mold surface to provide protection. At the same time, store them categorized by the mold's specifications and models for easy access.
Kunshan Fuze Testing Equipment Co., Ltd. provides mold maintenance guidance and high-quality mold replacement services to extend the service life of the molds.